PROVIDENT - FDAS
FIRE DETECTION ALARM SYSTEM
Fire alarm systems provide a means to detect and identify fire or a potential fire outbreak in a building, warn the occupants of the building about the fire via audible alarm and potentially notify emergency response professionals. The main components of a fire alarm system are typically the smoke detectors (and other detectors like heat, and gas detectors), manual call points (also called "break glass") which enable a person who physically detects fire to raise the alarm, bell or alarm sounders, flashers, and control panel (central control and indicating equipment) which is the brain of the system. Some advantages of fire alarms include an early warning benefit and the potential to save life and property, low cost, and the opportunity to place the device in chosen locations. It is a key recommendation in any fire prevention plan.
NW8200-4
NW8200-8/16
FIRE ALARM CONTROL PANEL - features a microprocessor-controlled, battery and energy interruption alarm, zone power, fault-led indicators, manual alarm, siren and reset buttons, access key, alarm output, and siren output with a relay.
Technical parameters:
Siren
Battery type
Alarm output
End of line resister
Detector connection
DC output
AC output
: Available
: 2 x 12V / 1.2Ah
: Relay
: 10k
: 20pcs (per each zone)
: 24VDC
: 220VAC
HD2-504
HEAT DETECTOR - This detector is conventional operates by advanced MCU expert algorithm software, and works perfectly with all conventional intelligent fire control panels with features:
• Dual LED for 360 visual
• Anti-RFI & Anti-EMI
• Flashing LEF power indicator
• High stability
• Low standby current
Technical specification:
Operating voltage
Wire
Operating temperature
Operating humidity
Standby current
Alarm current
Alarm output
Reset
Detecting rang
Dimension (mm)
: 9V ~ 40V
: 2 wires
: -10°C ~ +50°C
: ≤ 95%, relative humidity
: ≤ 55uA
: ≤ 55mA, DC24V
: Remot LED
: Power off
: 50sqm with an installation
height of 6m to 12m
: Ø100 x 52
SD2-604
SMOKE DETECTOR - This detector is a conventional photoelectronic smoke detector that uses an optical sensing chamber. This detector is designed to provide open area protection and to be used with conventional fire alarm control panels. It can enable a fire alarm when the temperature difference achieved the setting rate of rise temperature value reaches the setting fixed value. It is stable and reliable working performance.
Technical specification:
Operating voltage
Wire
Operating temperature
Operating humidity
Working current
Alarm current
Alarm output
Sensitivity
Dimension (mm)
: 9V ~ 35V
: 2 wires
: -10°C ~ +50°C
: ≤ 95% relative humidity
: ≤ 55uA
: ≤ 55mA, DC24V
: Remot LED
: 0.5dB/m (±0.1dB/m)
: Ø103 x 51
SSD-425
ALARM SMOKE DETECTOR - This detector is stand-alone and battery-operated with features:
• Infrared photoelectric sensor
• Automatic detection
• Automatic reset
• Sound-light alarm
Technical specification:
Battery
Battery type
Operating temperature
Operating humidity
Standby current
Alarm current
SPL
Reset
Dimension (mm)
• High stability
• Dust-proof
• Insect-proof
• Anti-visible light
: 9V
: 2 x 12V / 1.2Ah
: -10°C ~ +50°C
: ≤ 95% relative humidity
: ≤ 10uA
: ≤ 10mA, ≤50mA
: ≥ 85dB/m
: Power off
: Ø140 x 41
AB-400
ALARM BELL - Uses a high-quality micro-motor operating mechanism. This provides the bell with long reliability, low starting voltage, and extremely low current consumption. These features enable the use of more bells per circuit and greater alarm signal distribution than other conventional bells. This alarm bell is an excellent choice for use in fire, burglary, or general alarm applications.
Technical specification:
Size
Wire
Operating temperature
Operating voltage
Driving way
Audio alarm
Working current
Dimension (mm)
: 6 inches
: 2 wires
: -10°C ~ +50°C
: 24VCD
: Coil
: ≤ 95db
: ≤ 55uA
: Ø103 x 51
CP-501 (Manual)
CP-502 (Resettable)
MANUAL CALL POINT - A device that enables personnel to raise an alarm in the event of a fire incident by pressing a frangible element to activate the alarm system.
RESETTABLE CALL POINT - Low-powered device designed to mimic the feel of a break-glass, whilst offering the user the benefits and environmental advantages of a resettable operating element. The reset manual call points are compatible with most conventional fire alarm systems and safe to use in such areas as food processing plants and leisure centers where glass cannot be used.
Fire alarm call points should be installed at a height of 1.4 meters above floor level at easily accessible and conspicuous positions. This includes exit routes, at the entry floor landing of the staircase, and all exits to the open air.
Fire call points should also be spaced so that one may always be found within a maximum distance of 30 meters apart.
Technical specification:
Material
Operation voltage
Maximum current
Contact resistance
Maximum humidity
Dimension (mm)
: Plastic
: 24VDC
: 1 Amp
: ≤ 0.2 ohm
: ≤ 93RH±2%
: 87 x 87 x 51
SL-410L
SL-411L
FIRE ALARM SIREN WITH STROBE LIGHT - Used with fire alarm control panel. When the fire alarm control panel detects a fire, it will activate the alarm siren. The siren will send out both loud sounds and a quick flashlight to remind people to escape from the fire. It is suitable to be used in offices, shops, hotels, restaurants, etc. suitable for the majority of conventional fire alarm systems.
Features:
-
Sound can be selected
-
Ambulance
-
Police car
-
Fire engine
-
-
Long life of strobe: Min. 40000 times
-
Loud alarm sound: Min. 100dB
-
Strobe flash rate: 1 flash per second